Fire Protection and Insulation for Building Cables
Mica tapes for circuit integrity, PET film, CPR-compliant flame-retardant tape and water-blocking for building-cable manufacturers
Building cables must meet increasingly demanding fire-safety requirements: circuit integrity for evacuation and emergency systems, low smoke and toxic-gas emission per CPR, and protection against moisture in buried conduits. OR64 supplies the materials that allow cables to be built in compliance with IEC 60331, EN 50200 and the CPR Euroclasses. Permanent stock in Barcelona with in-house taping service.
Mica Tapes for Circuit Integrity
Safety cables in buildings — evacuation, alarms, sprinklers, lifts — must keep their function during a fire per IEC 60331 and EN 50200. OR64 mica tapes make it possible to build cables that meet these requirements. Halogen-free and free of toxic gases, compliant with the most demanding CPR Euroclasses.
MUSCOVITE FR80M28
→ Standard IEC 60331, EN 50200
PHLOGOPITE (FR-P series)
→ Long exposure, BS 6387
Muscovite Mica FR80M28
Standard grade IEC 60331, EN 50200. Maximum dielectric strength. Halogen-free.
View datasheet
Phlogopite Mica (FR-P series)
Higher thermal resistance up to 1000°C. Greater flexibility for small cross-sections. Halogen-free.
View datasheetCPR Flame-Retardant Tape
Euroclass compliance without mica
For cases where circuit integrity is not required but CPR compliance is — smoke emission and flame propagation. Non-woven polyester base with retardant elements, halogen-free. Contributes to Cca and Dca CPR Euroclasses.
Insulation and Separation
PET film and non-woven polyester
PET film provides dielectric insulation between layers (up to 16.9 kV). Non-woven polyester acts as separator, eases stripping and improves extrusion.
Moisture Protection
Water-blocking tapes for buried conduits
Cables in buried conduits or damp areas require protection against water ingress. Water-blocking tapes block the longitudinal advance of water when an insulation fault occurs.
Reference standards
OR64 materials enable the cable manufacturer to build products that meet the main fire-safety standards in building construction.
The Construction Products Regulation (CPR) classifies cables according to their fire behaviour in Euroclasses.
Mica Taping Service
OR64's in-house conductor mica-taping service. Five vertical double-head lines with 80 km/day capacity. Single or double-layer taping per standard. OR64 material or toll processing on customer conductor.
Slitting
Width up to 1200 mm · ±0.50 mm
Ver servicio
Spooling
OD up to 300 mm · TWS, STS
Ver servicioLocal Stock and In-House Taping Service
Permanent stock in Barcelona: 100 t/year of mica, 500 t of polyester. Taping service with 80 km/day capacity. No reliance on 8-12 week imports. No minimum order. ISO 9001 certification and full traceability.
Contact usTechnical or commercial enquiry
For a mica quote: specify type (muscovite/phlogopite), reference, width, format (pad/spool), volume. For taping service: specify conductor cross-section, target standard, estimated volume.
Permanent stock in Barcelona · 24-48h delivery